Cylindrical In-line photovoltaics fuse-links

Cylindrical In-line photovoltaics fuse-links

Cylindrical In-line photovoltaics fuse-links

ETI has developed its own solution for the In-line protection of photovoltaic modules against reverse currents. The solution is in cylindrical gPV fuse-links with crimp caps which are designed for direct crimping PV conductors with a corresponding crimping tool. Crimp connection allows connecting PV conductors cross-section from 4 to 6 mm2. Fuse-links are developed according to the IEC 60269-6, UL 248-19 and meet all In-line requirements.

 002626300_photo (1)

 

New VV fuse links with lower minimum breaking currents

New VV fuse links with lower minimum breaking currents

New VV fuse links with lower minimum breaking currents


Introducing a new line of medium-voltage fuses VV with low minimum breaking currents, high breaking capacity up to 63 kA, two types of striker pins: 50N and 80 N (with integrated temperature dependent limiter) and reliable sealing system against humidity irruption. VV fuses are used to protect distribution transformers, high-voltage motors, high-voltage capacitors, voltage transformers...

 vv_picture

 

New generation of 10x85 and 10/14 x 85 fuse-links 1500V gPV

New generation of 10x85 and 10/14 x 85 fuse-links 1500V gPV

New generation of 10x85 and 10/14x85 1500V gPV cylindrical fuse-links

 

A new generation of photovoltaic cylindrical fuse-links with nominal currents up to 32A and rated voltage up to 1500V is now available, with gPV characteristic for protection of solar panels against the reverse current. New fuse-links have a lower power dissipation and higher breaking capacity up to 50 kA. Size 10/14x85 has a patented design for interrupting in case of short circuit conditions.

EFI eV RCCBs - a reliable e-mobility protection

EFI eV RCCBs - a reliable e-mobility protection

EFI eV RCCBs - a reliable e-mobility protection


The EFI eV residual current circuit breaker is intended exclusively for the protection of electric vehicles' charging stations. It's main advantage is compatibility with the elements of the existing protection of the electrical installation, thus eliminating the need the replace the entire panelboard if we wish to install a home charging station.

EFI eV1

EFI-P - New series of Residual Current Circuit Breakers

EFI-P - New series of Residual Current Circuit Breakers

EFI-P - New series of Residual Current Circuit Breakers


ETI is launching new series of Residual current circuit breakers (RCCB) EFI-P.

 




Main Advantages:

-100%  automated control of all key parameters of each product

- Increased reliability

- Reduced power dissipation by up to 45%

 

Detailed info here: https://efi.etigroup.eu/



 
















 

 

 
 
The new ETI HXS standing enclosures of the SOLID GSX System

The new ETI HXS standing enclosures of the SOLID GSX System

The new ETI HXS standing enclosures of the SOLID GSX System


The ETI's offer was expanded with new metal free-standing HXS300 and HXS400 cabinets, while a wide range of additional and indoor equipment greatly enhances the scope of the entire SOLID GSX system.



Advantages:

• High versatility and flexibility of configuration

• Removable internal set (can be used in a workshop or in the building during installation)
• Covers and mounting plates dedicated to ETI equipment (circuit breakers, disconnectors, etc.)
• Quick assembly
• Three-point door locking system with toothed mechanism and lever with the option of being equipped with a system or patent insert
• Unscrewed rear wall with polyurethane poured gasket
• High-quality diaphragm glands from the top and double aluminum from the bottom
• Painted with polyester paint resistant to UV radiation
 
NEW AFDD - Arc fault Detection Devices series

NEW AFDD - Arc fault Detection Devices series

NEW KZS AFDD - Arc fault Detection Devices series


ETI is launching a new series of KZS AFDD - arc fault detection device with complete protection: miniature circuit breaker (MCB), residual current circuit breaker (RCCB) and arc fault protection (AFDD) in one device. Main purpose of the product is overcurrent and short circuit protection of both poles, with universal connection - supply is posible both from top and bottom terminals.



ETI products library on wscaduniverse

ETI products library on wscaduniverse

ETI products library on wscaduniverse


Wscaduniverse is the world´s biggest Electrical-WSCAD library and from now on there is also more than 4000 ETI products in the field of protection and contactors.

NH battery fuse link 1500V d.c.

NH battery fuse link 1500V d.c.

New series of NHXL battery fuse link 1500V d.c.


 ETI presents a completely new generation of NV/NH BATTERY fuse-links, designed for 1.500V d.c. 



General characteristics:
Rated voltage 1500V d.c. (L/R=3ms)
Breaking capacity 30kA d.c.
Standard IEC60269-7
Application Fuse link for DC application. Applied in fuse
base PK XL 1500V.

New series of space saving surge arresters ETITEC V

New series of space saving surge arresters ETITEC V

New series of space saving surge arresters ETITEC V


This power surge protective devices are designed to meet all your surge protection needs for any low voltage installation. DIN rail mounted surge protectors are easy to install in any standardized distribution panel or control cabinets. We have also extended our offer with compact versions of type 2 and type 3 surge protectors for limited space requirements.